| Model | SPW/37 | SPW/55 | SPW/73 | SPW/109 | Typical Production Speeds |
| Drying length mm | 1768 |
1288 1588 1948 |
1288 1588 1948 2308 |
1288 1588 1768 1948 2308 |
120 mtrs/min 150 mtrs/min 165 mtrs/min 180 mtrs/min 214 mtrs/min |
| Radio Frequency Generator 6kW, 12kW, 25kW | |||||||
| Maximum Possible Water Removable Rate | 6kW = 6 kgs/hr 12kW = 12 kgs/hr 25kW = 25 kgs/hr |
||||||
| Power output (Continuously Rated) | 6kW, 12kW, 25kW | ||||||
| Frequency Standard Mains Supply |
27.12 MHz ± 0.6% Stabilised (ISM Band) 360/440 Volt 3 Phase 50 Hz 440/510 Volt 3 Phase 60 Hz |
||||||
| Maximum Line Current |
|
||||||
Maximum Power Consumption |
|
||||||
Oscillator Valve |
|
||||||
| Rectifiers | Silicon Diodes | ||||||
back |
![]() |